DJF1000 Series Distributors , find complete details about DJF1000 Series Distributors , JPQ progressive distributors, JB/T8464-96, central lubrication - Haoli
Quantity: | |
---|---|
The DJF1000 Series distributors JB/T8464-96 distributes and proportions incoming oil or grease to bearing points. A typical DJF1000 distributor consists of an inlet section, three to nine valves and an end section. One assembly can serve up to a maximum of 18 lubrication points.
The DJF1000 Series distributors central lubrication have a sliding discharge piston and built-in outlet check valves. Blocks are offered in three output sizes. The discharge capacity of a block is determined by varying the piston diameter in the valve block. Valve blocks have two outlets located at each end of the assembly (double outlet blocks) and supply rated discharge outputs from each of the two outlets during one complete valve cycle.
Technical data
Max work pressure:16MPa
Delivery:0.08ml/cyc ~ 0.48ml/cyc
Lubricant viscosity (under
standard temperature):
oil≥N68;grease:NLGI 000#~2#
Work temperature:-20℃~+60℃
Max work frequency (with stem):60cyc/min
Max work frequency (without stem):200cyc/min
Manifold number:3~8
Tubing: Outlet: Φ4mm length: 0.5~2.5m
Inlet: Φ6mm length:1.2~3.5m
DJF-1000 Dimension
No. Of Working Segments | A (mm) | B (mm) | No. Of Working Segments | A (mm) | B (mm) |
3 | 59.3 | 80.0 | 6 | 104.6 | 125.0 |
4 | 74.7 | 95.0 | 7 | 119.6 | 141.0 |
5 | 89.5 | 110.0 | 8 | 134.7 | 156.0 |
DJF1000 Parameter
P.N. | Valve Size | Discharge | Max Pressure | Min Pressure | inlet Screw | Inlet Pipe | Outlet screw | Outlet pipe | Outlet per Segment |
mL/Cyc | MPa | ||||||||
20710 | 1000-5T | 0.08 | 16 | 1.4 | M10×1 | Φ6 | M8×1 | Φ4 | 2 |
20711 | 1000-05S | 0.16 | 1 | ||||||
20712 | 1000-10T | 0.16 | 2 | ||||||
20713 | 1000-10S | 0.32 | 1 | ||||||
20714 | 1000-15T | 0.24 | 2 | ||||||
20715 | 1000-15S | 0.48 | 1 |
Note:
1. Cycle indicator can be mounted on 1.5T or 1.5S sections;
2. User shall specify changed inlet/outlet diameter, when ordering;
3. Never block outlet of a distributor so as to avoid over pressure damage to the distributor;
4. Smallest segments group shall have 3 sections; largest segments group shall have 8 sections.
content is empty!